03-91
|
Recent Fault Log
(Shows faults in chronological order starting with the most recent. |
|
03-92
|
Fault Log (# of
occurrences of each fault code since log was last cleared). |
|
06-02 |
Vertical
Magnification (range is 0-40mm). |
|
07-00 |
Cut Length
Adjustment. |
|
07-60 |
Delay between
Film Prints. Increases the time delay between making prints on Film
Media (1-30 seconds). |
|
08-09 |
Enable or Disable
the Stack Height Sensor. |
|
08-60 |
Image
Registration (range is 0-40mm). |
|
09-04 |
Automatic ESV
(Electrostatic Voltage) Setup (this test steps through a test and
displays values when complete). |
|
09-06 |
Tone Up / Tone
Down (adjusts concentration to set point). |
|
09-21 |
Electrostatic
setup. * (read below for details) |
|
09-22 |
Disables toner
faults (select ‘Yes’ for running with toner faults, then use code
03-61 to exit to run mode). |
|
09-26 |
Reset Toner
Control Bias to default. |
|
09-55 |
Test Pattern from
memory (9 patterns available). |
|
09-70 |
Adjust test
pattern (used to help when testing the LED bar (code 09-21 option 5)
… allows you to change between two different patterns to see if the
LED array changes appropriately). |
|
10-04 |
Fuser Run Test
(automatically warms up the fuser and displays the thermistor
readings (both the edge and center readings) in Fahrenheit and
Celsius mind you! Once up to run temperature, the Drum / Developer
and Fuser Drive Motors are switched on… All interlocks must be
closed for this test to run). |
|
10-26 |
Resets the Fuser
Control NVM (memory settings) to the default settings. |
|
10-30
|
Reset Oil Web
counter. |