Tips Técnicos:
(technical
tips)
|
Xerox PE16
style(PE16/16i, PE120/120i) Fixing The Fusers! |
|
|
Modelos Xerox
PE16 Reparando Fusores! (PE 16 /16i, PE120/120i) |
|
Even
the lowest volume printer fusers can be worth fixing— the PE16
and PE120 fusers are good examples. An easy-to-disassemble
module, it’d be a shame to throw one away for just having a
worn out heat roller or worse, a broken fuser drive gear.
Modulo Fusor Xerox PE16 - Xerox PE16 Fuser Module
The parts are available and affordable, so let’s get
cracking. We’ll start with a bit of a comparison between our
two subjects (PE16 fusers vs. PE120 fuser), cover some of the
crossover models, part numbers and other such details, and
walk through stripping one of them down.
The two
versions of the fusers are PE16 and PE120, which you will find
have nearly identical disassembly procedures. Some parts do
cross over back and forth, but not all of them. The Fuser
Lamps are the same as one another and the Thermistor and
Thermal Fuse too, but that is about where the part crossovers
end. The Heat Roll on the PE16 is very small compared to the
PE120 version (and therefore the Heat Roll Bushings and Fuser
Drive Gear are also different). The Pressure Roll is
dimensionally the same. Oddly however the outer sleeves are
designed differently. The PE120 is one with that now familiar
black-sleeve over orange-foam which gets all wrinkly even in a
brand new fuser. The PE16 has a sleeved all orange silicon
roll. If I had to guess, the two Pressure Rollers are probably
interchangeable in spite of their design differences, but I’ve
not tested the theory yet. The Picker Fingers look very
similar one to another; however if you compare them closely,
the PE120 version is a little bit shorter than the PE16
version. They have plastic claws, but there is a coated-metal
cladding clipped onto them which actually makes contact with
the heat roll and handles stripping the paper from the roller.
There are an abundant number of other makes / models which
cross over to the PE16. Likewise, a few cross to the PE120.
This makes the fusers even more worthy of our attention (learn
one, learn them all). Here’s a quick list of some of the
models we have found to cross over:
| PE16 Fusers |
makes/models share the same
parts: |
|
Gestetner |
DSM-516PF, F250, F270, F290 |
| Lanier |
LF-125M, LF215M |
| Lexmark |
X215 |
| Rex-Rotary |
DSM-516PF, F250, F270, F290 |
| Ricoh |
AC-104, Aficio FX16,
Fax1130, Fax1170, Fax2210L |
| Samsung |
ML-1750, SCX-4016, SCX-4100,
SCX- 4116, SCX-4216 |
| Savin |
AC104 |
| PE120 Fusers |
makes/models share the same
parts |
| Dell |
1600N |
| Samsung |
ML-2250, ML-2551N, SCX-4520,
SCX- 4720F |
|
Hasta el más bajo volumen de fusores de impresión vale la pena
repararlo. Los Fusores para PE16 Y PE120 son un muy buen
ejemplo de ello, ya que sería una pena tirarlos solo por el
hecho de tener fracturas en el fusor de velocidad o el rodillo
de calor desgastado, estos son muy fáciles desmontar, sus
partes son accesibles y disponibles en el mercado, para
entenderlo mejor haremos una pequeña comparación entre Fusores
PE16 Y Fusores PE120, mencionando a detalle cada uno de ellos,
como modelos que pueden ser usados para ellos y números de
parte.
De las dos versiones que hay en fusores PE16 y
PE120, cual pensaría usted que es más parecida al proceso de
desmontaje? Algunas partes pasan de adelante para atrás pero
no todas ellas. La lámpara de fusor es igual que los
termistores con sensibilidad térmica, pero todo esto es sobre
el hecho de cual termina al final. El rodillo de calor en PE16
es muy pequeño comparado con la versión del PE120 (por lo
tanto, el rodillo de calor, el buje y el rodillo de velocidad
son diferentes también). El rodillo de presión es el mismo en
tamaño, sin embargo, y curiosamente las fundas exteriores
están diseñadas diferentes. El PE120 es el que conocemos con
funda negra sobre foam naranja que queda arrugado hasta en los
fusores de marcas nuevas. El PE16 tiene fundas naranjas con
rodillos de silicón. Si tuviera que adivinar entre los dos
rollos de presión que son muy similares y seguramente
intercambiables con algunas diferencias de diseño, pero no me
he comprobado esa teoría hasta el momento. Las uñas de
separación parecen muy similares la una de la otra, sin
embargo, si se comparan a detalle, la versión del PE120 es más
corta que la versión del PE16. Tienen garras de plástico, hay
un metal de revestimiento cortado entre ellas que es el que
hace el contacto con los rodillos de calor y se encarga de la
extracción del papel que viene del rodillo.
Hay un
numero abundante de otras marcas / modelos que pueden ser
usados para PE16. Del mismo modo, que algunos para la PE120.
Esto hace que valga la pena tomar atención en los fusores
(aprender de uno, aprender de todos ellos). He aquí una lista
rápida de algunos otros modelos que hemos encontrado con el
tiempo:
| Fusores PE16 |
modelos que comparten las
mismas partes: |
|
Gestetner |
DSM-516PF, F250, F270, F290 |
| Lanier |
LF-125M, LF215M |
| Lexmark |
X215 |
| Rex-Rotary |
DSM-516PF, F250, F270, F290 |
| Ricoh |
AC-104, Aficio FX16,
Fax1130, Fax1170, Fax2210L |
| Samsung |
ML-1750, SCX-4016, SCX-4100,
SCX- 4116, SCX-4216 |
| Savin |
AC104 |
| Fusores para PE120 |
Modelos que comparten las
mismas partes: |
| Dell |
1600N |
| Samsung |
ML-2250, ML-2551N, SCX-4520,
SCX- 4720F |
|
The PE16 Fuser is spared under the part number 126N214 (Xerox
sells it for $) and the PE120 uses the number 126N233 (Xerox
price is $). Xerox is spotty about which pieces of these
fusers they spare on their parts lists. The Heat Roller and
Fuser Drive Gear are spared on the PE16 but not on the PE120.
For both versions, the Heat Lamp, Thermistor, and Thermal Fuse
are spared, but the Picker Fingers are not. Don’t worry; there
are quality generic products now available which fill in most
of the blanks.
Now for a brief procedure for you.
There are only a couple of real gems in the write-up which
will help you avoid problems; mostly it’s rather
straight-forward. |
Fusores PE120 modelos que comparten las mismas partes 126N124
(Xerox vende por $.-) y el PE120 está bajo el numero de parte
126N233 (El precio de Xerox es $.-) Xerox es irregular sobre
cuales repuestos de estas piezas estarán en su lista de
partes. El repuesto para el rodillo de calor y el fusor de
velocidad de la PE16 si se encuentra en la lista pero para la
PE120 no. Para las dos versiones, las lámparas de calor, el
termistor con sensibilidad térmica tienen repuesto, pero las
uñas de separación no. No se preocupe; hay productos genéricos
disponibles de gran calidad para llenar estos vacios.
Ahora un breve procedimiento para usted. Tocando algunos
puntos importantes, lo que le ayudara a evitara problemas en
el futuro ya que la instrucciones son muy sencillas. |
 |
 |
 |
 |
 |
 |
Foto #1 -
Orientación
Photo #1
- Orientation |
Foto #2 - Extremo Izquierdo (Engrane)
(No pierda los pequeños tornillos de la lámpara de la
terminal que están en cada extremo)
Photo #2 - Right End (Geared) (Don’t lose the
little nuts from the lamp terminal’s screws – one
at either end) |
Foto # 3 - Lado del papel de entrada
mover la cubierta principal (4 tornillos)y guía de
Entrada (2 tornillos) Photo #3
- Paper Entry Side Remove Top Cover (4 screws) & Entry
Guide (2 screws) |
Foto #4 - Ensamblado de la cubierta
principal (interior)(Termistor de sensibilidad
térmica, unas de separación etc.) Photo #4
- Top Cover Assembly (inside)(Thermistor, Thermal
Fuse, Fingers, etc.) |
Foto #5 - Ver Parte Inferior (Salida
del brazo de soporte , este se libera deslizándolo
hacia un lado) Photo #5 - Bottom
View (Exit Acuator Mounting Bracket, remove by
releasing and sliding over |
Foto #6 - Remueva el Rodillo de Calor
(Mantenga los separadores para proteger el rodillo )
Photo #6 - Heat Roll Removal (Keep
that bushing in there to protect the roller) |
|
Fuser Repair/Rebuild Procedure:
Orientation: We’ll refer to the “Left End” (Geared end) of the
fuser and the “Right End” (opposite the geared end). There is
also a “Paper Entry Side” and a “Paper Exit Side” (that is the
one with the Picker fingers stripping the paper as it exits
the Fuser). We’ll consider the black plastic cover with the
Thermal Fuse and Thermistor in it to be the “Top Cover”
although I confess I have yet to see how the fuser is actually
oriented in a machine in this respect.
1.
Remove the Fuser Lamp and put it someplace safe. Its
flat metal contacts are held on by two screws, one at either
end. Retrieve the tiny nuts (one at either end) which the
screws were threaded into (they will fall right out once the
screws are removed and are easily lost). Notice for reassembly
purposes that the screw at the Right End (opposite the geared
end) also secures a wire which leads to the heat lamp
connector.
2. With the lamp out, it’s safe to
remove the Top Cover Assembly which houses the
Thermistor, Thermal Fuse, and Picker fingers. Remove two
screws from the top which secure the black plastic Top Cover,
followed by two from the Paper Entry Side of the fuser (See
Photo #3). Remove the Double Idler Gear (15/25 Teeth) (1 screw
holds it on) and then the tiny Single Idler (16T) will slide
right off for you. There is another Single Idler Gear (23T)
which is clipped on; it is captive so you can choose to leave
it in place or remove it depending on your mood.
3. You can now get to the Thermal Fuse, Thermistor and
Picker Fingers which are all mounted in the Top Cover
Assembly. The Thermal Fuse (thermostat) is held on by two
screws. The Thermistor’s head has a single screw securing it
from the bottom. Note that with the Top Cover off, the Picker
Fingers spring to a position which will get in the way when
you go to put the cover back on. If you are not careful during
reassembly, the fingers will get trapped above the heat roll
and will likely do some serious damage to that roller. We’ll
mention that again in the reassembly step of the procedure.
4. There are some goodies in the Lower Frame
Assembly as well (Fuser Drive Gear, Exit Switch Actuator, &
Exit Roller): Remove the Fuser Drive Gear. With the
Top Cover off, the Fuser Drive Gear will slide right off the
end of the Fuser Heat Roller. The Exit Switch Actuator and its
spring are mounted on a little plastic holder bracket which
can be removed by releasing a catch on the bottom to allow the
bracket to slide towards the Left End (Geared End) of the
fuser (See Photo #5). The Exit Roller can be removed easily
too. Two little plastic anchors hold it in place.
5. Now for the Heat Roller. First take off the black
plastic entry guide from the Paper Entry Side (2 screws)
(Refer back to Photo #3). This is actually very
important because if it remains in place when the Heat Roll is
removed, the Pressure Roll will want to push up against the
sharp little protrusions on this entry guide and the Pressure
Roll’s surface is likely to get damaged at least cosmetically.
Keep the Heat Roll Bushings in position in the metal frame.
They will help keep pressure off the Heat Roll, and they
protect the Heat Roll’s surface as you slide it out the Left
End (geared end) (See Photo #6). 6. Next the
Pressure Roller. Once you remove the Heat Roll
Bushings (turn them a quarter revolutions to release them from
the metal frame), the Pressure Roller becomes removable from
its cradle-shaped, spring-loaded Bushings.
7.
Reassembly reminders & tips: When you go to reinstall
the Heat Roll, put the two Bushings in place on the frame to
take some of the Pressure Roll’s pressure off and to protect
the surface of the Heat Roll from scraping against the metal
frame. When reinstalling the Top Cover, use both hands
to retract all 4 Picker Fingers as you lower the Top
Cover down over the Heat Roll so that the fingers are properly
positioned against the Heat Roll instead of being sprung to
their natural position above the Heat Roll (they won’t do any
stripping of paper up there and are likely to do damage to the
Heat Roll’s surface).
That’s all there is to it!
By the way, when you go to put the Fuser Module back
in, the Fuser Messages on these machines are all cleared by
turning the power off, waiting 30 seconds, and then turning
the power back on (there is no diagnostic reset required).
Here are some of the Fuser Error Messages you might
see:
CRU Fuser Error Heating Error
Open Heat Error Over Heat
The “Open
Heat Error” message actually means the fuser is seen to be
“under-temperature”. This error will show up whenever the
machine fails to heat up. It can come up if the Fuser Lamp is
out or if the machine has overheated and blown the Thermal
Fuse and therefore failed to warm up after being powered off
and back on.
I hope that’s enough to keep us all
heading up the green path. Recycle these fusers— don’t throw
them out! See you all next month.
Britt works for
The Parts Drop - Visit The Parts Drop’s website at
www.partsdrop.com. |
Reparacion de Fusor / Procedimiento de Reconstruccion:
Orientación: Nos referiremos “Extremo Derecho” (Engrane
mayor) del fusor y “Extremo Izquierdo” (al contrario del
engrane mayor). También hay un “Documento de Entrada” y
“Documento de Salida” (que es donde se en del papel que viene
del fusor). Vamos a considerar la cubierta de plástico negra
con el termistor de sensibilidad térmica que sea la “Cubierta
Principal” aunque he de confesar que no he visto aun como está
orientado el fusor en esta máquina.
1. Remueva
la lámpara de fusor y colócala en un lugar seguro. El
metal plano que tiene 2 tornillos en cada esquina, destornille
cada uno de ellos, teniendo mucho cuidado ya que son fáciles
de perder. Atención para propósitos de re armar asegure el
tornillo del Extremo derecho (al contrario del engrane mayor)
y el cable principal que conecta la lámpara de calor.
2. Con la lámpara fuera de la maquina es seguro quitar
la cubierta principal, que cubre el termistor de
sensibilidad térmica y las uñas de separación, remueva los dos
tornillos superiores que aseguran la cubierta principal negra
, seguido de la esquina del documento de entrada del fusor
(ver foto#3). Remueva doblemente el engrane de velocidad
(15/25 T)(1 desarmador sosteniéndolo) después hay otro simple
y pequeño engrane (16t) que se deslizara hacia afuera de su
lado derecho. Ahí hay otro simple engrane de velocidad (23T)
que está encapsulado, Es su opción dejarlo en su lugar o
removerlo depende de su humor.
3. Ahora usted
puede llegar al Fusor Térmico y a las uñas de separación,
los cuales están montados en la cubierta principal del
ensamble. El fusor termal (termostato) esta sostenido por 2
tornillos. La cabeza del termistor tiene un solo tornillo que
la asegura de la parte inferior. Atención con la cubierta
fuera de la maquina, las uñas de separación se colocan en una
posición que quedan en el camino para poner la cubierta en su
lugar, Si usted no tiene cuidado durante la re construcción,
los separadores quedaran atrapados debajo del rodillo de calor
y esto ocasionara un gran daño al rodillo. Mencionaremos esto
nuevamente en el procedimiento de re construcción.
4. Hay algunos objetos de cuidado en el marco inferior
como (Fusor de Velocidad, Switch de salida y el rodillo de
salida): Remueva el Fusor de Velocidad, con la
cubierta principal afuera de la maquina, el fusor de
velocidad, se encuentra en el extremo del lado derecho del
fusor de calor. El switch de salida está montado en un pequeño
brazo de plástico que puede ser removido liberando la parte
inferior del soporte que permite al soporte deslizarse hacia
el extremo izquierdo (engrane mayor) del fusor (ver foto #5).
La salida del rodillo puede ser removida fácilmente también.
Solo son dos ganchos de plástico lo que la sostienen.
5. Ahora par el Rodillo de Calor. Primero coloca
afuera el plástico negro que es la esquina de guía de entrada
del papel (2 desarmadores) (referencia la parte
trasera de la foto #3). Esta de hecho es muy importante si
permanece en su lugar cuando el rodillo de calor es removido,
la presión del rodillo la empujara hacia arriba donde
encontrara una protuberancia filosa hacia la guía de entrada
de la superficie de los rodillos de presión, es posible que se
dañen al menos cosméticamente. Mantenga los rodillos de calor
separándolos en posición del marco de metal. Ellos ayudaran a
mantener la presión afuera del rodillo de calor, y protegen la
superficie del rodillo de calor que se desliza hacia afuera
del extremo izquierdo. (engrane mayor ) (Ver foto #6).
6. Siguiente Rodillo de Presión: Una vez que
remueva el rodillo de calor separe, (de un cuarto de vuelta
para liberarlos del marco de metal), el rodillo de Presión se
empieza a remover del objeto en forma de cuna.
7. Reconstrucción, Recomendaciones y Tips: Cuando
usted re instale el Rodillo de Calor, ponga 2 separadores
sobre el marco para que no toda la presión caiga sobre los
rodillos de presión, de esta forma protegerá la superficie del
rodillo de calor y no raspara el marco de metal.
Cuando re instale la cubierta principal, use ambas manos para
retirar los cuatro picos de las uñas de separación
como de la cubierta más baja de los rodillos de calor, para
que los separadores estén propiamente en su lugar en contra
del rodillo de calor, en lugar de que se encuentre sostenida
en posición natural por debajo del rodillo de calor (No se
hace ningún tipo de limpieza con documentos en esa parte, ya
que es probable que se haga daño al rodillo de calor de la
superficie)
Eso es todo!
Por cierto si Usted va
a poner el Modulo del Fusor, el Fusor de mensajes en estas
maquinas estará vacio cuando lo apague por 30 segundos,
préndalo de nuevo (no se necesita diagnosis).
Estos son
algunos mensajes que Usted podría ver, enviados por el Fusor
de ERROR:
CSU Error en el Fusor Error de
Calentamiento Error de Calentamiento de Entrada
Sobrecalentamiento
El Mensaje de Calentamiento
de Entrada significa que el fusor esta debajo de temperatura.
Este error se muestra cuando la maquina falla en el
calentamiento. Puede ser porque la lámpara del fusor está
descompuesta o si la maquina se sobre calentó, quemo el fusor
térmico y por lo tanto, falló el calentamiento después de ser
apagada y encendida otra vez.
Espero que esto sea
suficiente para mantenernos en la Ecología, reciclando
fusores- No los tires!, Nos vemos el mes siguiente.
Britt trabaja para la compañía Parts Drop -Visita el sitio de
la compañía Parts Drop
www.partsdrop.com. |
|
|
|